PHE III Voltage Detector
Nominal Voltages up to 30 kV / 50 Hz
- Safe verification of isolation from supply voltage
- Reliable indication
- Easy to use
- Cost-effective / space-saving transport
Nominal Voltages up to 30 kV / 50 Hz, M12 Thread
Nominal Voltage Ranges up to 30 kV / 50 Hz, M12 Thread
Nominal Voltage Ranges up to 30 kV / 50 Hz, M12 Thread, switchable
Nominal Voltages up to 25 kV / 50 Hz
Nominal Voltages up to 30 kV / 50 kV, Gear Coupling
Nominal Voltage Ranges up to 30 kV / 50 Hz, Gear Coupling
Nominal Voltage Ranges up to 36 kV / 50 Hz, Gear Coupling, switchable
Nominal Voltage Ranges up to 30 kV / 50 Hz, Test Kit, Thread M12
Nominal Voltage Ranges up to 30 kV / 50 Hz, Test Kit, Gear Coupling
The nominal voltage selector switch allows to switch between two nominal voltage ranges. For safety reasons, the voltage detector can only be switched on if the selector switch is switched to the most sensitive range of 3 kV to 10 kV. The switch snaps into the relevant position, thus providing protection against inadvertent switching. A magnetically operated, wear-resistant reed switch changes the switching position.
Category "S" for switchgear installations and overhead lines.
For the overhead contact lines of electric railways.
Category "S" for single-ended monophase systems.
The nominal voltage selector switch allows to switch between two nominal voltage ranges. For safety reasons, the voltage detector can only be switched on if the selector switch is switched to the most sensitive range of (3 kV to 10 kV or 6 kV to 20 kV). The switch snaps into the relevant position, thus providing protection against inadvertent switching. A magnetically operated, wear-resistant reed switch changes the switching position.
Category "S" for switchgear installations and overhead lines.
With two test prods of Category "S" for switchgear installations and overhead lines and of Category "L" for overhead lines.
For extending the handle of IS ... STK insulating sticks using an ES SQ or ES SQL earthing stick.
For Eaton Holec Magnefix switchgear installations of type MA, MD4, MF, MG, MY.
For switchgear installations with limited access (e.g. Calor Emag/Isopond and Krone/KES).
Not suitable for use in wet weather conditions
For switchgear installations with limited access.
Not suitable for use in wet weather conditions
For switchgear installations with limited access.
Not suitable for use in wet weather conditions
For switchgear installations with limited access and remotely situated contacts.
Not suitable for use in wet weather conditions
For substations and switchgear installations that require a greater insertion depth.
Not suitable for use in wet weather conditions
Category "S" for PHE III voltage detectors (Part Nos. 767 721, 767951, 767 722, 767 740 and 767940).
Category "S" for PHE III voltage detectors (Part No. 767 731 and 767 750).
Plug-in coupling at both ends for extending the insertion depth or the handle.